| Cooling supply chain → AI Data Centers | Thermal infrastructure Air or liquid cooling must suit racks and facilities; the approaches can coexist. | Delta | Data-center air and liquid cooling 2026-09-26 |
| Cooling supply chain ↔ AI Servers | Thermal-load-driven design Power and density affect server cooling; not all AI servers use the same liquid-cooling architecture. | Delta | Data-center air and liquid cooling 2026-09-26 |
| Cooling supply chain → Air cooling modules | Air cooling route | DOE | Energy-efficient data center design guide 2026-10-01 |
| Cooling supply chain → Direct-to-chip cold plates | Cold-plate cooling route | OCP | Cold plate development and qualification 2026-10-01 |
| Cooling supply chain → Immersion cooling systems | Immersion cooling route | Submer | SmartPod EVO single-phase immersion 2026-10-01 |
| Thermal interface materials → Air cooling modules | Reduce contact resistance Scope note 1 | Shin-Etsu | Thermal interface materials 2026-10-01 |
| Thermal interface materials → Direct-to-chip cold plates | Chip-to-cold-plate interface Scope note 1 | OCP | Cold plate development and qualification 2026-10-01 |
| Heat pipes and vapor chambers → Air cooling modules | Transport and spread heat Scope note 1 | TaiSol | Heat pipes, vapor chambers and thermal modules 2026-10-01 |
| Heat sinks and fins → Air cooling modules | Bases and cooling fins Scope note 1 | TaiSol | Heat pipes, vapor chambers and thermal modules 2026-10-01 |
| Cooling fans and fan walls → Air cooling modules | Forced-air components Scope note 1 | Sunon | Fans and air-assisted liquid cooling 2026-10-01 |
| Cold-plate loop coolants → Direct-to-chip cold plates | Loop heat transfer fluid Scope note 1 | Dow | Propylene-glycol coolant for direct-to-chip loops 2026-10-01 |
| Liquid cooling quick disconnects → Direct-to-chip cold plates | Serviceable loop connections Scope note 1 | Staubli | Liquid cooling connectors for data centers 2026-10-01 |
| Liquid cooling quick disconnects → Cooling tubing and manifolds | Connect cooling branches Scope note 1 | nVent | Rack manifolds and tubing 2026-10-01 |
| Cooling pumps and drives → Coolant distribution units | Circulation pumps Scope note 1 | Nidec | 2026 pumps, drives and CDU technologies 2026-10-01 |
| Heat exchangers → Coolant distribution units | Inter-loop heat exchange Scope note 1 | Delta | CDUs and data center cooling products 2026-10-01 |
| Dielectric immersion fluids → Immersion cooling systems | Compatible dielectric fluid Scope note 1 | Shell | Single-phase immersion cooling fluids 2026-10-01 |
| Heat exchangers → Immersion cooling systems | System heat exchange Scope note 1 | Submer | SmartPod EVO single-phase immersion 2026-10-01 |
| Air cooling modules → Server and rack cooling integration | Platform-specific air cooling Scope note 1 | DOE | Energy-efficient data center design guide 2026-10-01 |
| Direct-to-chip cold plates → Server and rack cooling integration | Chip-side liquid modules Scope note 1 | ASUS | Server and rack liquid cooling integration 2026-10-01 |
| Cooling tubing and manifolds → Server and rack cooling integration | Distribution and return plumbing Scope note 1 | Auras | 2024 annual report: cold plates, manifolds and CDUs 2026-10-01 |
| Coolant distribution units → Server and rack cooling integration | Circulation and control integration Scope note 1 | ASUS | Server and rack liquid cooling integration 2026-10-01 |
| Server and rack cooling integration → AI Servers | Server and rack integration Scope note 1 | QCT | 2026 liquid-cooled AI rack solutions 2026-10-01 |
| Facility cooling and heat rejection → AI Data Centers | Facility cooling infrastructure Scope note 1 | Trane | Data center cooling equipment 2026-10-01 |
| Direct-to-chip cold plates ↔ Cooling tubing and manifolds | Cold plates and manifolds share a loop | CoolIT | Cold plates, loops, manifolds and CDUs 2026-10-01 |
| Cooling tubing and manifolds ↔ Coolant distribution units | Loop connection and flow matching | CoolIT | Cold plates, loops, manifolds and CDUs 2026-10-01 |
| Coolant distribution units ↔ Facility cooling and heat rejection | Connect according to CDU architecture Liquid-to-liquid connects to facility loops; liquid-to-air first transfers heat to air for site rejection. | DOE | Energy-efficient data center design guide 2026-10-01 |
| Immersion cooling systems ↔ Facility cooling and heat rejection | Facility heat rejection for immersion | Submer | SmartPod EVO single-phase immersion 2026-10-01 |
| Immersion cooling systems ↔ AI Data Centers | Optional data center cooling architecture | Submer | SmartPod EVO single-phase immersion 2026-10-01 |
| Cooling fans and fan walls → Coolant distribution units | Airflow for liquid-to-air designs Applies to air-assisted configurations, not every CDU. | Sunon | Fans and air-assisted liquid cooling 2026-10-01 |
| Heat pipes and vapor chambers → Smartphones | Thin mobile-device cooling | TaiSol | Mobile device cooling 2026-10-01 |
| Direct-to-chip cold plates ↔ Network Switches | Liquid cooling option for switches | QCT | Liquid-cooled network switch 2026-10-01 |
| Heat sinks and fins ↔ AI PCs and Workstations | PC and workstation cooling designs | TaiSol | Industrial PC heat sinks 2026-10-01 |
| Cooling supply chain ↔ CPO platforms & systems | Thermal design | NVIDIA | Optical integration, coupling, packaging and ELS 2026-10-01 |
| Server rack system integration → Direct-to-chip cold plates | Cooling branch Scope note 2 | NVIDIA | MGX architecture and system partners 2026-10-05 |
| Direct-to-chip cold plates → Compute trays and server modules | Chip cooling for compute modules Scope note 2 | NVIDIA | MGX mechanical, power and cooling roles 2026-10-05 |
| Liquid cooling quick disconnects → Rack design and system integration | Serviceable coolant interfaces Scope note 2 | NVIDIA | MGX mechanical, power and cooling roles 2026-10-05 |
| Cooling tubing and manifolds → Rack design and system integration | Coolant distribution and return Scope note 2 | NVIDIA | MGX mechanical, power and cooling roles 2026-10-05 |
| Coolant distribution units ↔ Rack design and system integration | Match equipment-side cooling loops Scope note 2 | Vertiv | Integrated rack infrastructure 2026-10-05 |
| Server and rack cooling integration → Rack design and system integration | Integrate thermal design and controls Scope note 2 | NVIDIA | MGX mechanical, power and cooling roles 2026-10-05 |
| Facility cooling and heat rejection ↔ Delivery, installation and site acceptance | Prepare facility cooling Scope note 2 | Vertiv | Integrated rack infrastructure 2026-10-05 |
| Thermal interface materials → Server PSU modules | Thermal interfaces selected for heat paths Scope note 3 | Henkel | Thermal interfaces and electrically insulating materials 2026-10-08 |
| Heat sinks and fins → Server PSU modules | Component heat-removal structures Scope note 3 | Infineon | 12 kW PSU specifications, control and protection 2026-10-08 |
| Cooling fans and fan walls → Server PSU modules | Forced convection for air-cooled designs Scope note 3 | Infineon | 12 kW PSU specifications, control and protection 2026-10-08 |
| Cooling supply chain → Desktop personal computers | Platform-dependent thermal management Product function and industry roles; no company-to-company purchasing contract is asserted. | ASUS | Motherboard specifications 2026-10-30 |
| Cooling supply chain → Notebook computers | Portable-system thermal management Product function and industry roles; no company-to-company purchasing contract is asserted. | AMD | Processors and graphics 2026-10-30 |
| Cooling supply chain → Desktop graphics cards | Graphics-card thermal integration Product function and industry roles; no company-to-company purchasing contract is asserted. | ASUS | Graphics cards 2026-10-30 |